Heat shrink cold shrink push on and slip over cable accessories enable the jointing terminating and connection of 11kv 33kv and 66kv 132kv cables to oil air or gas insulated.
Cable joints and terminations pdf.
Distribute cable containment including cablofil cable basket unitrunk cable tray and vantrunk speedway cable ladder systems.
Preinsulated twist on type shall be permitted on solid conductor size no.
Shall be hydraulic compression long barrel type with application preformed insulated cover heat shrinkable tubing or plastic insulated tape.
3 cable connections in joints and terminations 27 3 1 introduction 27 3 2 types of connectors used in cables 28 3 3 current path 29 3 4 methods of conductor connections 31 3 5 contact resistance 40 3 6 preferred methods in practice for different cable ratings 41 3 7 galvanic corrosion and use of bimetals 41.
Supply lv hv heat shrink cold shrink cable joints and terminations cable glands cable cleats earthing feeder pillars cable laying and electrical eqpt.
T d distribute the most extensive range of hv high voltage cable joints terminations connectors from manufacturers including 3m prysmian nexans euromold elastimold pfisterer connex and shrink polymer systems.
98 www jointingtech co uk mv terminations 11kv indoor termination part number conductor size ixsu f 3111 10 35mm2 ixsu f 3121 25 95mm2 ixsu f 3131 95 240mm2 part number conductor size 92 ep621 1 50 95mm2 92 ep631 1 120 400mm2 part number conductor size.
Wire cable and terminations november 2004 design guidelines and standards 3wct splices 600 volt.
Supplied with epoxy resin for use where there is a risk of water seepage or high humidity during curing.
Shall be solderless type only.
The supplied length of cable is not sufficient to perform the intended job e g only so much cable can be wound on a reel the reel ends or only so much cable can be pulled through so much conduit around so many bends etc.
Low voltage joints terminations low voltage resin joints 3m 92 a joints high humidity up to 1 kv un armoured inline joint for armoured unarmoured pvc xlpe cables moisture resistant for high humidity areas.
Cable joints terminations and cables accessories course overview this course will provide a history of the development of cable accessories review standards and type testing.
Specification for joints stop ends and outdoor terminations for distribution cables of rated voltage 0 6 1 0 kv iec 61238 1 compression and mechanical connectors for power cables for rated voltages up to 30 kv um 36 kv part 1.
Test methods and requirements en 50393 test methods and requirements for accessories for use on distribution.